0
HSL-3-R Heavy-duty wedge anchor

HSL-3-R Heavy-duty wedge anchor

Hilti Fastener: HSL-3-R Heavy-duty wedge anchor
Product Name:HSL-3-R Heavy-duty wedge anchor
Anchor size: M8-M20
Anchor length: 93-170
Material, corrosion: Stainless steel, A4
Head configuration: Hex head
Approvals / test reports: BZS/shock, ETA, Fire
Base materials: Concrete (cracked), Concrete (uncracked)
Type of fastening: Through-fastening
PROFIS software: Yes
Quantity
Contact Now
add to cart

1.Product Overview – HSL-3-R Heavy-duty wedge anchor
HSL-3-R Heavy-duty wedge anchor fuses A4-stainless strength with through-fastening simplicity for seismic and shock-proof steel connections.

A4 stainless resists corrosion in C3–C5 zones

Hex head torque-tightens with standard tools

Through-fastening slashes installation time

ETA fire & BZS shock certified for cracked concrete

2. HSL-3-R Heavy-duty wedge anchor Technical Parameters

Parameter

Specification

Notes

Anchor size

M8 / M10 / M12 / M16 / M20 / M24

Metric thread

Length range

93–170 mm

Overall length

Embedment hef

60–120 mm

Size-dependent

Materia

A4 stainless steel

EN 1.4401 / 316

Base concrete

C20/25–C50/60

Cracked & uncracked

3. HSL-3-R Heavy-duty wedge anchor Performance Data

Size

Embedment

TTension NRk*

Shear Vrec*

M8

60 mm

20.0kN

45.7 kN

M12

90 mm

35.2 kN

70.4 kN

M16

120 mm

49.2 kN

98.4 kN

M20

120 mm

65kN

127.7kN

*Characteristic values, cracked concrete

20 % higher shear than DIN anchors in same hole

Fatigue tested ≥ 2 million cycles at 0.6 NRk

Fire classification R90 retains 60 % load

4. HSL-3-R Heavy-duty wedge anchor Installation Guide

Step

Action

Tools/Requirements

1

Mark hole

Marker

2

Hammer drill

SDS-Plus bit

3

Clean hole

Brush & blow twice

4

Insert anchor

Hand push

5

Tighten hex

Socket wrench

6

Load immediately

Ready

5. HSL-3-R Heavy-duty wedge anchor Application Scenarios

Application

Recommended Spec

Conditions

Nuclear pump base

M12 × 110 mm

Cracked C30/37, wind

Steel column shoe

M16 × 150 mm

Seismic C2, shock

Façade sub-frame

M10 × 100 mm

Outdoor C3, R90 fire

Bridge parapet

M20 × 170 mm

Fatigue, vibration

6. HSL-3-R Heavy-duty wedge anchor Certifications & Compliance

ETA-21/0740 – cracked & uncracked concrete C20/25–C50/60

BZS/shock – tested 1.5 g horizontal shock load

Fire – R90 (ISO 834), retains ≥ 60 % NRk

CE-marking – EN 1992-4:2018 & EN 15129

Send Message