HSA-F HDG Wedge anchor
Anchor size: M8/M10/M12/M16/M20
Anchor length: 55 mm-225 mm
Pack size: 10 pc/16 pc/25 pc/40 pc/50 pc/80 pc/100 pc
1. Product Overview
HSA-F HDG Wedge anchor – A robust mechanical anchor for secure fastening in uncracked concrete.
High-strength, hot-dip galvanized carbon steel bolt for superior load capacity
Corrosion-resistant stainless steel sleeve for long-term durability
Complete assembly with washer and nut for a fully certified securing system
2. HSA-F HDG Wedge anchor Technical Parameters Table
Parameter | Specification | Notes |
Bolt Material | Carbon Steel 1.0501 / 1.1172 (18MnV5) | High-tensile strength |
Corrosion Protection | Hot-dip galvanized (242 μm) | Excellent corrosion resistance |
Sleeve Material | Stainless Steel A2, 1.4301 | / |
Nut Strength Class | DIN 934 Class 8 | / |
Washer Standard | DIN 125, 140HV | / |
Operating Temp. Range | -40°C to +80°C | In-service temperature |
3. HSA-F HDG Wedge anchor Performance Data
The system is designed for high tensile and shear loads in uncracked concrete, offering reliable and predictable performance.
High Load Capacity: Engineered for demanding static and dynamic loads.
Corrosion Resistance: The combination of hot-dip galvanization and a stainless steel sleeve ensures durability in various environmental conditions.
Material Compatibility: Optimized interaction between bolt and sleeve for smooth expansion and secure setting.
Proven Reliability: Consistent performance backed by rigorous testing and certifications.
4. HSA-F HDG Wedge anchor Installation Guide Table
Step | Action | Tools/Requirements |
1 | Drill hole to correct diameter | Rotary hammer, carbide-tipped drill bit |
2 | Clean hole of all dust and debris | Wire brush, air blower, vacuum |
3 | Insert anchor assembly into hole | Hand setting |
4 | Tighten nut to secure anchor | Standard wrench or socket |
5 | Apply final torque to specification | Torque wrench |
5. HSA-F HDG Wedge anchor Application Scenarios
Application | Recommended Spec | Conditions |
Structural Steel Connections | M16, M20 | Uncracked Concrete, C20/25 |
Machinery & Equipment Base Plates | M12, M16 | Indoor, Dry Environment |
Pipe Supports & Cable Trays | M10, M12 | Uncracked Concrete |
Safety Barriers & Railings | M12, M16 | Static loading conditions |
6. Certifications & Compliance
(1) ETA (European Technical Assessment) approved for cracked and uncracked concrete.
(2) Compliant with European Assessment Document EAD 330232-00-0601.
(3) Tested for seismic loading conditions (ETA category C1).
(4) Evaluated for fire resistance according to ETA.
(5) Fatigue loading performance assessed and certified.
Send Message