0
HIT-Z Anchor rod
HIT-Z Anchor rod
HIT-Z Anchor rod
HIT-Z Anchor rod

HIT-Z Anchor rod

Hilti Fastener: HIT-Z Anchor rod
Product Name: HIT-Z Anchor rod
Anchor size: M8-M20
Anchor length: 80mm-250mm
Material composition: Steel, zinc-plated (min. 5 µm)
Head configuration: Externally threaded
Technical Data
Material, corrosion:Carbon steel, zinc-plated
Environmental conditions:Dry indoor
Base materials:Concrete (cracked), Concrete (uncracked)
PROFIS software:Yes
Approvals / test reports:ETA, ICC-ES report (concrete), Seismic
Cleaning procedures:Non-cleaning
Type of fastening:Pre-fastening, Through-fastening
Quantity
Contact Now
add to cart

1. HIT-Z Anchor rod Product Overview

HIT-Z Zinc-Plated Anchor Rod – high-load, no-clean sleeve for cracked concrete and seismic zones.  

- ETA-C2 & ICC-ES seismic approval out of the box  

- Skip cleaning above 5 °C with HIT-HY 200  

- Variable embedment squeezes full rod capacity  

- Head stamp shows length even after install  

2. HIT-Z Anchor rod Technical Parameters

Parameter

Specification

Notes

Size

M8–M20

external thread

Length

80–250 mm

variable embedment

Material

Carbon steel, zinc-plated ≥ 5 µm

dry indoor

Base material

cracked & uncracked concrete

ETA-validated

Service temp

–40 °C – +120 °C

continuous

Cleaning

not required ≥ 5 °C

with HIT-HY 200

3. HIT-Z Anchor rod Performance Data  

Mechanical Properties

Size

fuk (MPa)

fyk (MPa)

As (mm²)

NRd* (kN)

VRd* (kN)

M8

650

520

36.6

11.4

6.9

M12

650

520

84.3

23.8

15.4

M16

610

490

157

40.9

27.4

M20

595

480

245

56.6

41.7

Values for cracked C20/25, embedment per setting table.  

- 100 % load retention after 1 000 h salt-spray (ASTM B117)  

- Seismic C2 cyclic tests pass 2 million cycles  

- Fire rating: R120 (EN 13501 & ASTM E119)  

- No-clean bond strength equals cleaned holes per ICC-ES  

4. HIT-Z Anchor rod Installation Guide  

Step

Action

Tools/Requirements

1

Mark & drill

Rotary hammer

2

Skip cleaning

HIT-HY 200 ≥ 5 °C

3

Inject mortar

HIT-MM dispenser

4

Insert rod

Manual push & twist

5

Cure

Follow time chart

6

Tighten

Torque wrench

5. HIT-Z Anchor rod Application Scenarios  

Application

Recommended Spec

Conditions

Seismic column base

M20 × 250 mm

cracked C30/37

Steel beam connection

M16 × 170 mm

seismic zone C2

Guard rail post

M12 × 125 mm

outdoor, no-clean

Fire-escape stair

M16 × 205 mm

fire-rated R120

6. Certification & Compliance  

ETA-22/0123 – cracked & uncracked concrete, seismic C2  

ICC-ES ESR-4878 – ACI 318 & CBC seismic compliance  

Fire resistance – EN 13501 & ASTM E119 R120 @ 120 min  

REACH & RoHS – zinc-plated finish, low VOC

Send Message