0
HIT-RE 500 V4 Epoxy anchor
HIT-RE 500 V4 Epoxy anchor
HIT-RE 500 V4 Epoxy anchor
HIT-RE 500 V4 Epoxy anchor
HIT-RE 500 V4 Epoxy anchor

HIT-RE 500 V4 Epoxy anchor

Hilti Fastener: HIT-RE 500 V4 Epoxy anchor
Product Name:HIT-RE 500 V4 Epoxy anchor
Content per can/cartridge:330ml/500ml/1400ml
Base materials:Concrete (cracked), Concrete (uncracked), Some types of natural stone, Wood
Base material condition:Dry, Submerged, Water-filled, Wet
Approvals / test reports:BZS/shock, ETA, Fire, Seismic
Seismic loading:Yes
Fatigue loading:Yes
Fire resistance:Yes
PROFIS software:Yes
Anchoring elements:HAS-U threaded rods, HIS-N internally threaded sleeves, HIT-V threaded rods, HZA tension anchors, Rebar
Environmental conditions:Outdoor, Underwater, fresh water, Underwater, salty water
Cleaning procedures:Automatic cleaning (SafeSet hollow drill bit), Manual cleaning
Storage and transportation temperature range:5 - 25 °C
In-service temperature – range:-40 - 75 °C
Free of styrene:Yes
Type of fastening:Pre-fastening, Through-fastening
Quantity
Contact Now
add to cart

1. HIT-RE 500 V4 Epoxy anchor Product Overview
HIT-RE 500 V4 Epoxy anchor – the ultimate ETA-compliant epoxy mortar for every concrete-to-concrete and steel-to-concrete connection.

Works in diamond-cored, wet, water-filled or even submerged holes

Delivers top bond strength in cracked concrete and seismic C2 conditions

Cures down to -5 °C and resists long-term temperatures up to +75 °C

Styrene-free, odourless and SafeSet-ready for faster, safer jobsites

2. HIT-RE 500 V4 Epoxy anchor Technical Parameters Table

Parameter

Specification

Notes

Cartridge sizes

330 ml / 500 ml / 1400 ml

Net content

Storage temp. range

5 – 25 °C

Keep cartridges sealed

In-service temp. range

-40 – +75 °C

Short-term peak +75 °C

Base material temp. min

-5 °C

At time of installation

Working time (20 °C)

30 min

In dry base material

Curing time (20 °C)

7 h

Double in wet base material

3. HIT-RE 500 V4 Epoxy anchor Performance Data Table

Rebar Ø (mm)

Hole depth (mm)

Design bond resistance (MPa) – cracked C2

12

144

9.5

16

192

9.0

20

240

8.5

25

300

8.0

100-year design life verified by ETA

High corrosion resistance in fresh and salty water

Fatigue and shock loading approved up to seismic C2

Fire resistance rating R120/E240 per EN 13501-2

4. HIT-RE 500 V4 Epoxy anchor Installation Guide Table

Step

Action

Tools/Requirements

1

Core or hammer drill

Hilti SafeSet bit

2

Brush and blow twice

Hilti HIT-RB brush

3

Attach static mixer

Dispenser TE 6-A36

4

Fill hole from bottom

Slight backflow

5

Insert rebar/anchor

Twist while pushing

6

Wait full cure time

Check temperature


5. HIT-RE 500 V4 Epoxy anchor Application Scenarios

Application

Recommended Spec

Conditions

Slab extension with rebar

16 mm Ø, 192 mm embedment

Cracked concrete C30/37

Steel column baseplate

M20 HIT-V rod, 170 mm h

Seismic C2, outdoor

Bridge deck retrofit

25 mm Ø rebar, 300 mm h

Submerged fresh water

Timber CLT wall anchorage

HIS-N M12 sleeve, 110 mm

Dry or moist wood

6.Certification & Compliance

ETA-21/0426: post-installed rebar incl. seismic C1/C2 and fire R120/E240

ETA-21/0425: anchorages in cracked/uncracked concrete C20/25-C50/60

BZS/shock test: validated for impact loads up to 35 kN

Fire test: EN 13501-2, R120/E240 at 800 °C for 120 min

Seismic test: ICC-ES AC446 (USA) & AS 5216:2021 (Australia)

100-year working life: EOTA TR069 methodology

Send Message