Capacity per can/magazine: 0.58 l
Substrate: Concrete (without cracks)
Substrate condition: Dry, wet
seismic load:No
Fatigue load:No
fire prevention: No
PROFIS software: No
Anchorage: HIT-V fully threaded screw, steel reinforcement
Environmental conditions: Indoor, brief humidity/condensation, outdoor (more than 1 kilometer away from the coast), dry indoor, high corrosion special applications (such as tunnels, swimming pools)
cleaning procedures: Manual cleaning
Storage and transportation temperature range: 5 - 25 °C
Temperature Range in Service: -40 - 55 °C
Free of styrene: yes
quality inspection: pass
Benefits :
- Suitable for non-cracked concrete
C20/25 to C50/60
- Suitable for dry and water
saturated concrete
- Suitable for overhead fastenings
Quantity
Contact Now
add to cart

1. Product Overview

HIT-RE 10 injection mortar - Hilti's advanced chemical anchoring solution for superior performance in non-cracked concrete applications.

Excellent performance in both dry and water-saturated concrete

Reliable overhead installation capability

Suitable for static and quasi-static loading conditions

Compatible with hammer drilling installation methods

2. HIT-RE 10 injection mortar Technical Parameters

Parameter

Specification

Notes

Cartridge Size

580 ml

Hard cartridge

Concrete Grade

C20/25-C50/60

Non-cracked concrete

Installation Method

Hammer drilling

Variable embedment depth

Load Type

Static/Quasi-static

Service Temperature

-40°C to +70°C

After curing

Base Material

Concrete

Dry/wet conditions

3. HIT-RE 10 injection mortar Performance Data

Performance Advantages:

Provides high bond strength in various concrete conditions

Maintains consistent performance in overhead applications

Offers reliable load capacity for structural applications

Ensures long-term durability in diverse environmental conditions

4. Installation Guide

Step

Action

Tools/Requirements

1

Drill hole

Hammer drill

2

Clean hole

Brush, blower

3

Inject mortar

Dispensing tool

4

Insert anchor

Manual placement

5

Cure properly

Time dependent

5. Application Scenarios

Application

Recommended Spec

Conditions

Structural anchoring

HIT-RE 10

Non-cracked concrete

Overhead installations

HIT-RE 10

Dry/wet conditions

Rebar connections

HIT-RE 10

Static loading

Equipment mounting

HIT-RE 10

Quasi-static loads

6. Certifications & Compliance

Hilti Technical Data Certification (2017-11-28)

Complies with EN 1992-4 anchor design standards

Suitable for non-cracked concrete applications

Approved for static and quasi-static loading conditions

Validated for use in dry and water-saturated concrete