HIT-FP 700 R Injectable cementitious
Approvals / test reports: DIBt, ETA, Fire, Seismic
Seismic loading: Yes
PROFIS software: Yes
Storage and transportation temperature range:5 - 25 °C
Shelf life from date of manufacture (at 23°C and 50% relative humidity):12 months
Product options:Injectable mortar HIT FP 700 R 500 1/INT #2330578
1* Foil pack
1* Mixer
1* Mixer extension
1. Product Overview
HIT-FP 700 R Injectable cementitious – the fire-rated cementitious mortar that bonds like cast-in rebar up to 500 °C.
Survives 500 °C fire, keeps bond strength
Works with SafeSet for faster, error-free installs
12-month shelf life, 100-year ETA life
Fits existing Hilti dispensers, zero learning curve
2. HIT-FP 700 R Injectable cementitious Technical Parameters Table
Parameter | Specification | Notes |
Cartridge volume | 500 ml | Single-use foil pack |
Storage temperature | 5 – 25 °C | Keep dry |
Service temperature | 40 – +160 °C | Max long-term +100 °C |
Min install temperature | +5 °C | Base material |
Shelf life | 12 months | At 23 °C / 50 % RH |
Concrete grade range | C12/15 – C50/60 | Dry & water-saturated |
3. HIT-FP 700 R Injectable cementitious Performance Data Table
Rebar Ø (mm) | Embedment depth (mm) | Fire bond strength at 500 °C (MPa) |
12 | 144 | 7.5 |
16 | 192 | 7.0 |
20 | 240 | 6.5 |
25 | 300 | 6.0 |
100-year ETA durability validated
Non-corrosive to rebar elements
Creep tests: 180 days at 100 °C, stable displacements
Ready for seismic C2 and fire R120 conditions
4. HIT-FP 700 R Injectable cementitious Installation Guide Table
Step | Action | Tools/Requirements |
1 | Mark hole | Measuring tape |
2 | Drill with SafeSet | Hilti hollow bit |
3 | Clean hole | Vacuum cleaner |
4 | Attach mixer | HDE dispenser |
5 | Fill hole | Full depth |
6 | Insert rebar | Twist while pushing |
5. Application Scenarios
Application | Recommended Spec | Conditions |
Fire-rated slab extension | 16 mm Ø, 192 mm depth | R120 fire, C30/37 |
Bridge deck splice | 25 mm Ø, 300 mm depth | Seismic C2, wet concrete |
New column head connection | 20 mm Ø, 240 mm depth | +160 °C service peak |
Diaphragm wall starter bars | 12 mm Ø, 144 mm depth | Water-saturated C40/50 |
6. Certification & Compliance
DIBt approval: Z-21.4-208 for fire resistance up to 500 °C
ETA-21/0743: static, fire and 100-year working life at 23 °C
Seismic test: cyclic loading per EN 1998-1, C2 category
Fire test: R120/E240 per EN 13501-2 at 500 °C for 120 min
Creep test: EAD 330087, 180 days at 100 °C, displacement < 0.3 mm
Send Message