0
HIT-FP 700 R Injectable cementitious
HIT-FP 700 R Injectable cementitious
HIT-FP 700 R Injectable cementitious
HIT-FP 700 R Injectable cementitious
HIT-FP 700 R Injectable cementitious

HIT-FP 700 R Injectable cementitious

Hilti Fastener: HIT-FP 700 R Injectable cementitious
Product Name:HIT-FP 700 R Injectable cementitious
Approvals / test reports: DIBt, ETA, Fire, Seismic
Seismic loading: Yes
PROFIS software: Yes
Storage and transportation temperature range:5 - 25 °C
Shelf life from date of manufacture (at 23°C and 50% relative humidity):12 months
Product options:Injectable mortar HIT FP 700 R 500 1/INT #2330578
1* Foil pack
1* Mixer
1* Mixer extension
Quantity
Contact Now
add to cart

1. Product Overview

HIT-FP 700 R Injectable cementitious – the fire-rated cementitious mortar that bonds like cast-in rebar up to 500 °C.

Survives 500 °C fire, keeps bond strength

Works with SafeSet for faster, error-free installs

12-month shelf life, 100-year ETA life

Fits existing Hilti dispensers, zero learning curve

2. HIT-FP 700 R Injectable cementitious Technical Parameters Table

Parameter

Specification

Notes

Cartridge volume

500 ml

Single-use foil pack

Storage temperature

5 – 25 °C

Keep dry

Service temperature

40 – +160 °C

Max long-term +100 °C

Min install temperature

+5 °C

Base material

Shelf life

12 months

At 23 °C / 50 % RH

Concrete grade range

C12/15 – C50/60

Dry & water-saturated

3. HIT-FP 700 R Injectable cementitious Performance Data Table

Rebar Ø (mm)

Embedment depth (mm)

Fire bond strength at 500 °C (MPa)

12

144

7.5

16

192

7.0

20

240

6.5

25

300

6.0

100-year ETA durability validated

Non-corrosive to rebar elements

Creep tests: 180 days at 100 °C, stable displacements

Ready for seismic C2 and fire R120 conditions

4. HIT-FP 700 R Injectable cementitious Installation Guide Table

Step

Action

Tools/Requirements

1

Mark hole

Measuring tape

2

Drill with SafeSet

Hilti hollow bit

3

Clean hole

Vacuum cleaner

4

Attach mixer

HDE dispenser

5

Fill hole

Full depth

6

Insert rebar

Twist while pushing

5. Application Scenarios

Application

Recommended Spec

Conditions

Fire-rated slab extension

16 mm Ø, 192 mm depth

R120 fire, C30/37

Bridge deck splice

25 mm Ø, 300 mm depth

Seismic C2, wet concrete

New column head connection

20 mm Ø, 240 mm depth

+160 °C service peak

Diaphragm wall starter bars

12 mm Ø, 144 mm depth

Water-saturated C40/50

6. Certification & Compliance

DIBt approval: Z-21.4-208 for fire resistance up to 500 °C

ETA-21/0743: static, fire and 100-year working life at 23 °C

Seismic test: cyclic loading per EN 1998-1, C2 category

Fire test: R120/E240 per EN 13501-2 at 500 °C for 120 min

Creep test: EAD 330087, 180 days at 100 °C, displacement < 0.3 mm

Send Message