FF RF or RTJ Choose the Right Flange Face or Pay the Price Later
Flange faces decide whether a joint leaks. Flat face, raised face and ring type joint solve the same sealing problem three different ways, and each one demands a matching gasket, a matching bolt-up discipline and a matching service. Pick the face wrong and the joint does not just lose product — it loses the safety margin the whole system was designed around, starting with the flange gaskets trapped between the two faces.
Face Geometry and Gasket Pairing
The face type stamped into the flange marking is the single most important field for the joint: it fixes which gasket seats on the flange and how the bolt load reaches it.
| Face | Geometry | Gasket pairing | Typical service |
|---|---|---|---|
| FF (flat face) | Entire face flat, no protrusion | Full-face soft gasket | Low pressure, ambient temperature, non-critical |
| RF (raised face) | Raised ring about 1/6 in (1.5 mm) high | Soft, spiral wound, graphite or PTFE | Most industrial duty, medium to high pressure |
| RTJ (ring type joint) | Machined ring groove, trapezoidal or oval | Solid metal ring gasket | High temperature, high pressure, hazardous media |
Face dimensions and gasket rules follow ASME B16.5 practice; check the joint drawing for the facing actually specified.
- FF (flat face) — the whole face is flat, with no protrusion or groove. The contact area is the largest of the three, so it needs a full-face soft gasket — rubber or compressed non-asbestos fibre — and even bolt loading to seal at all.
- RF (raised face) — a raised ring about 1/6 inch (1.5 mm) high concentrates bolt load onto a narrow band, so the gasket seals harder with less torque. It takes soft, spiral wound, flexible graphite or PTFE gaskets and is the most common face in industry.
- RTJ (ring type joint) — a machined ring groove with a trapezoidal or oval section takes a solid metal ring gasket that plastically deforms into the groove for a metal-to-metal seal. It is the heavy-duty face for extreme pressure and temperature.
Installation Discipline per Face
Each face sets its own assembly rules; ignoring them wastes the geometry.
- FF — lay the full-face gasket between the faces and tighten the bolts evenly in a cross pattern; the large contact area makes torque sequence and torque control critical, since uneven loading leaks.
- RF — seat the gasket on the raised ring, with the gasket bore slightly larger than the pipe bore and the outer diameter just inside the bolt circle; the raised band does the sealing work once the bolts are down.
- RTJ — the metal ring must match the groove dimensions exactly. Drop the ring into the groove of one flange, bring the mate into alignment and tighten slowly and evenly; the ring flows into every corner of the groove, and over-tightening deforms it past the design point and hurts the seal. Use the defined torque sequence and hardened washers against galling.
Matching the Face to the Service
Environment picks the face far more reliably than price does.
- FF — low pressure, ambient temperature, non-critical lines: cast iron or low-pressure stainless assemblies with rubber or fibre gaskets. Not for high temperature, high pressure or hazardous media.
- RF — the all-rounder for chemical, petroleum, natural gas and power service, from medium to high pressure, with graphite, PTFE or spiral wound gaskets covering most media.
- RTJ — high-temperature and high-pressure systems, hazardous media and zero-leakage critical duty: petrochemical units, high-temperature steam and offshore platforms. Higher first cost and strict installation, but the reliability under extreme conditions is not replaceable.
Selection is a balance of pressure class, temperature range, media, budget and install conditions: FF is the economical answer on light duty, RF the best cost-performance for the bulk of projects, RTJ the mandatory answer where a leak is not an option. On pipe flanges an RF face cannot be converted to RTJ by swapping parts — the groove geometry forces a full flange pair replacement.
Frequently Asked Questions
Can an RF gasket be used on an FF flange?
No. An FF joint needs a full-face gasket. A ring gasket on a flat face overloads the centre and leaks.
Which face is cheapest up front?
FF costs the least to machine but caps the pressure class. For the majority of projects, RF gives the best balance of performance and cost.
Does RTJ need special bolts?
The bolts are standard for the class, but the joint needs a strict torque sequence and hardened washers to keep the metal ring from galling.
Can an existing RF flange be converted to RTJ?
No. The groove geometry is completely different, so the whole flange pair has to be replaced rather than re-faced.
Why does RF seal with less bolt load than FF?
The raised ring concentrates the load on a narrow band instead of spreading it across the whole face, so the gasket reaches sealing stress at lower torque.
Slip-On Flange vs Socket Weld Flange: The 5-Minute Guide to Choosing Right
Stop Guessing: The Ultimate Cheat Sheet for Reading Flange Markings
Related Article