C4430 Insulating Spacer
One-Minute Overview
- C4430 Insulating Spacer is supplied for 4 Inch ASME B16.5 150LB flanges with G10 sleeves, washers and ZPS.
- Staged cross-pattern tightening keeps the Klingersil C4430 element evenly compressed.
- Sleeves must span the full grip length and sit square under every washer.
- Torque values and stack height are confirmed per inquiry.
Most isolation joint failures trace back to assembly practice rather than the gasket itself. C4430 Insulating Spacer pairs a Klingersil C4430 element with G10 sleeves, washers and ZPS for ASME B16.5 150LB flanges in 4 Inch. Correct bolt sequence and a square insulating stack are what preserve both the seal and the dielectric break over time.
Name: C4430 Insulating Spacer
Material: Klingersil C4430
Compound: aramid fibre with a nitrile binder
Standard: ASME B16.5
Size: 4 Inch
Pressure: 150LB
Complete with: G10 sleeves and washers with ZPS
Note: Full dimensions and bolt pattern are confirmed per inquiry.
Before fitting, verify the ASME B16.5 bolt circle, the 150LB rating and the available grip length. Choose the 4 Inch gasket so the bore clears the pipe, then confirm that each sleeve is long enough for the assembled stack; a sleeve that ends short of the washer leaves a live metal path.
Clean and inspect both faces, set the gasket concentric with the bore, and tighten in at least three cross-pattern passes to the torque defined by the flange and bolt grade. Seat sleeves and washers square, then recheck the joint after the first heat-up because creep and thermal growth relax bolt load. Finish by measuring electrical continuity across the flange.
FAQ
Q1. What bolt sequence is recommended for this kit?
Q2. How do I know the insulating sleeves are fitted correctly?
Q3. Why is a torque recheck needed after start-up?
Q4. What's the minimum I can order?